How Much Space, Ceiling Height and Power Does a 5D Cinema or Flying Theater Need?
The lowest Waku theater fits under a 3 m ceiling in a 6 × 6 m room. Minimum room, clear height and power for every model, how to measure clear height, and what to tell us about your power supply.

The 5D flying theater fits the lowest ceiling: 3 m of clear height in a 6 × 6 m room. The Bermuda Adventure needs the least floor, about 6 × 5 m, with 3.2 m of height; the track cinema needs 6 × 8 × 3.2 m and the dome flying theater 6 × 6 × 3.8 m. All models run on 380 V three-phase power, with estimated power by configuration of about 10–45 kW (5D), 10–15 kW (track), 20–60 kW (dome) and 12–28 kW (Bermuda). Add space for a queue and a ticket point to these room sizes.

What is the minimum room for each model?
| Model | Seats | Minimum room (L × W × H) | Floor area | Power |
|---|---|---|---|---|
| Bermuda Adventure | 15 / 20 / 30 | 6 × 5 × 3.2 m (typical) | 30 m² | 380 V, about 12 / 16 / 28 kW, by configuration |
| 5D flying theater | 10 / 16 / 30 / 60 | 6 × 6 × 3 m | 36 m² | 380 V, about 10–45 kW, by configuration |
| Dome flying theater | 8 / 16 / 24 / 32 | 6 × 6 × 3.8 m | 36 m² | 380 V, about 20–60 kW, by configuration |
| Track cinema | 10 / 15 | 6 × 8 × 3.2 m | 48 m² | 380 V, about 10–15 kW, by configuration |
The room sizes are for the smallest version of each model. Larger seat counts need a larger room; we draw the layout for the version you choose.

How do I measure clear height correctly?
Measure from the finished floor to the lowest object above the theater area: a beam, a duct, a sprinkler pipe, a cable tray or a light fitting. The slab-to-slab height of the building is not the figure to use. Measure at several points across the room, because beams and ducts are rarely level with each other, and use the lowest reading.

Which model fits a low ceiling?
| Clear height | Models that fit |
|---|---|
| 3.0–3.19 m | 5D flying theater |
| 3.2–3.79 m | 5D flying theater, track cinema, Bermuda Adventure |
| 3.8 m and above | All four models, including the dome flying theater |

What power supply does a 5D cinema or flying theater need?
Waku theaters are specified for 380 V three-phase power. Many countries supply 230/400 V three-phase, the IEC 60038 standard voltage, while North America commonly uses 208 V or 480 V three-phase. Send us your local voltage and frequency (50 or 60 Hz) with the inquiry, and we specify the supply for your country.
The kW figures are estimates of the maximum draw for each configuration; we confirm the exact figure with the quotation. Use it to size the supply and the breaker. For energy cost, multiply rated power by opening hours for an upper limit: a 20-seat Bermuda Adventure at about 16 kW uses at most about 160 kWh in a 10-hour day.
What else does the site need besides the theater room?
- Queue and ticket area in front of the entrance, sized for one show’s guests waiting while the previous show runs.
- Exit route separate from the entrance, so the next group can board while the last one leaves.
- Delivery access: door widths, lift sizes and permitted delivery hours.
- Floor load: share the building’s floor loading limit with us so we can check the layout.
What should I send to check my site?
A floor plan with dimensions, the clear height, a photo of the ceiling, your local voltage and frequency, and the seat count you want. Send your site details and we will confirm which model fits and send a layout drawing.
Once the room fits, the next questions are money: see what a flying theater or 5D cinema costs and how to estimate ticket revenue.
Frequently asked questions
What is the lowest ceiling a Waku theater can fit under?
3 m, for the 5D flying theater in a 6 × 6 m room.
Does the room size include the queue?
No. The sizes are for the theater room; add a queue and ticket area in front of it.
Can the theaters run on 400 V or 480 V supply?
Tell us your local voltage and frequency; we specify the power supply for your country with the quotation.
Which model needs the most height?
The dome flying theater, from 3.8 m for the 3.8 m dome; larger domes need taller rooms.
Can the room size be adjusted?
Yes. The sizes are minimums from the parameter sheets, and the layout is adjusted to your floor plan.
Talk to the factory
Tell us your country, venue size and ceiling height. We reply with a recommendation and a quotation.